Water pressure sensor fault
Breakdown: the boiler is stopped
The sensor that measures the water pressure is sending an abnormal signal (short circuit or open circuit), or, on older GB162 boilers, the measured pressure is too high. The boiler locks out for safety.
What you can do
- Write down the code shown, the number next to it if there is one, and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show C0?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
Choose a real expert
Ecowatt is an approved Buderus System Partner: factory training in Germany, direct access to spare parts, one contact.
The variants of code C0
The small number shown beside the code tells which.
The operating pressure is too high (> 5.7 bar) or the pressure sensor is malfunctioning
The contacts of the pressure sensor are short-circuited
Water pressure sensor open circuit
Water pressure sensor faulty (short circuit)
The boilers that show this code
What our technician checks
- The operating pressure (below 3 bar)
- The pressure sensor connector
- The cable and the sensor: open circuit or short circuit
- The pressure sensor, replaced if necessary