No flame detected at ignition
Blocking: it retries by itself
During or just after ignition, the boiler does not detect any flame. The boiler stops temporarily and restarts by itself once the fault is cleared.
What you can do
- Write down the code shown, the number next to it if there is one, and the boiler model (on the rating plate).
- Check that the boiler's gas shutoff valve is open.
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show 2927?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
Choose a real expert
Ecowatt is an approved Buderus System Partner: factory training in Germany, direct access to spare parts, one contact.
The variants of code 2927
The small number shown beside the code tells which.
No flame detection signal during ignition
The boilers that show this code
What our technician checks
- The gas shutoff valves (main and appliance) and the gas line
- Ignition and ionization (function check, current measured with a microammeter), and the ground connection (PE)
- The ignition and monitoring electrodes, their cables and connectors
- The burner setting (minimum rated load) or its nozzles
- The gas valve; on the GB272, the air-gas control valve and the flue gas non-return valve
- The flue gas exhaust, the combustion air supply and the ventilation opening
- The heat exchanger on the flue gas side, cleaned
- The control unit or the burner control unit, replaced if necessary