Temperature too high: safety device tripped
Breakdown: the boiler is stopped
A temperature safety device has shut down the boiler: the safety sensor, the heat exchanger limiter or the flue gas limiter has measured a temperature that is too high. If the fault persists, the boiler locks out.
What you can do
- Write down the code shown, the number next to it if there is one, and the boiler model (on the rating plate).
- Check the water pressure: at least 1 bar, or the needle in the green zone of the pressure gauge. Too low? Top up with the boiler cold, the way your installer showed you.
- Check that enough radiators are open.
- Bleed the radiators, then check the water pressure again.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show 4C?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
Choose a real expert
Ecowatt is an approved Buderus System Partner: factory training in Germany, direct access to spare parts, one contact.
The variants of code 4C
The small number shown beside the code tells which.
The heat exchanger temperature limiter or the flue gas temperature limiter has tripped
The boilers that show this code
What our technician checks
- The water pressure, and venting of the system and the boiler
- The circulation: water flow rate, pump start-up and setting; pump replaced if necessary
- The safety temperature sensor
- The heat exchanger limiter, the flue gas limiter and their cables (open circuit, short circuit)
- GB172i: the flue, the differential pressure switch and its tube
- The circuit board fuse
- The water circuit of the heat exchanger and its displacers (distributors)