Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Buderus Fault code Buderus
1025

Return temperature sensor faulty

Blocking: it retries by itself

The sensor that measures the temperature of the water coming back from the system is faulty. The boiler keeps running, possibly with limited functions.

What you can do

  1. Write down the code shown, the number next to it if there is one, and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show 1025?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

Buderus

Choose a real expert

Ecowatt is an approved Buderus System Partner: factory training in Germany, direct access to spare parts, one contact.

The variants of code 1025

The small number shown beside the code tells which.

1025

The return temperature sensor is faulty

Blocking: it retries by itself GB192i, GB192i.2, GB272

The boilers that show this code

What our technician checks

  • The return sensor connector
  • The return sensor, measured with an ohmmeter and compared with the manufacturer's table; replaced if needed
  • The sensor cable, repaired or replaced
  • The control unit, which reads the sensor signal; replaced if needed

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.