Flow temperature rising too fast
Blocking: it retries by itself
In the heat exchanger, the flow water temperature is rising too fast. This is not a lockout: the boiler starts again by itself as soon as the cause is gone.
What you can do
- Write down the code shown, the number next to it if there is one, and the boiler model (on the rating plate).
- Check that enough radiators are open.
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show 2966?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
Choose a real expert
Ecowatt is an approved Buderus System Partner: factory training in Germany, direct access to spare parts, one contact.
The variants of code 2966
The small number shown beside the code tells which.
Flow temperature rising too fast in the heat exchanger
The boilers that show this code
What our technician checks
- The circulation of the heating water
- The pump setting, adapted to the system
- The connectors on the temperature sensor and the control unit
- The temperature sensor mounting
- The sensor and its connection cable, replaced if necessary