Breakdown: the boiler is stopped
F.00 Flow temperature sensor disconnected
F.01 Return sensor fault or ignition fault
F.078 Accessory or control module misconfigured
F.087 Ignition not connected to the circuit board
F.088 Gas valve not connected
F.089 Heating pump incompatible or badly connected
F.10 Flow sensor short or return sensor fault
F.11 Return sensor short or display link fault
F.13 Cylinder sensor short or main board fault
F.20 Overheating or incompatible interface
F.22 Not enough water or pressure too high
F.23 Temperature difference or poor water circulation
F.24 Temperature rising too fast
F.25 Flue gas temperature too high
F.27 Flame detected with the burner off
F.28 Ignition failure or sensor mismatch
F.29 Flame lost during operation, relighting failed
F.32 Fan not running correctly
F.49 eBUS line fault (controls)
F.61 Gas valve control fault
F.62 Delayed gas valve shut-off
F.63 Circuit board memory (EEPROM) fault
F.64 Electronics or sensor fault
F.65 Electronics temperature too high
F.67 Implausible flame signal
F.68 Unstable flame signal
F.70 Invalid boiler identification
F.71 Flow sensor stuck on one value
F.72 Flow and return sensor mismatch
F.73 Water pressure sensor: signal too low
F.74 Water pressure sensor: signal too high
F.75 Pump fault or lack of water
F.77 Flue gas flap or condensate pump fault
F.83 Temperature does not rise at burner start
F.84 Implausible flow-return temperature difference
F.85 Flow and return sensors wrongly fitted
F.86 External safety contact open (underfloor heating)
F.97 Main circuit board self-test failed