Pump fault or lack of water
Breakdown: the boiler is stopped
When the pump starts, the boiler does not see the water pressure rise as expected: lack of water or air in the heating, pump stuck or faulty, or pressure sensor faulty. This is a fault: the boiler stops and our technician has to find the cause before putting it back into service.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Look at the heating water pressure on the display: if it is too low, top it up as the boiler's user manual explains.
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.75?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.75
The meaning depends on the boiler: find yours below.
The pressure rise when the heating pump starts is insufficient
Fault: pump, lack of water
Fault: no pressure change detected when the pump starts
Pump fault / lack of water
Fault: pressure sensor
The boilers that show this code
What our technician checks
- The system pressure, filling and venting
- The heating pump: seizure, power supply, diagnostic D.149; replaced if faulty
- The water pressure sensor, replaced if faulty
- The adjustable bypass and the expansion vessels (the external one on the return)
- The pump wiring harness (LIN cable)