Flow temperature sensor disconnected
Breakdown: the boiler is stopped
The boiler no longer receives the signal from its flow temperature sensor, which measures the water sent to the heating: the sensor, its cable or a connector is at fault. It is a fault code that needs a technician; the one exception is the ThermoMaster HR TOP, where F0 means "no fault".
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.00?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.00
The meaning depends on the boiler: find yours below.
Flow temperature sensor open circuit
Flow sensor open circuit
Flow temperature sensor open circuit
Fault: flow temperature sensor
The flow temperature sensor signal is interrupted
no fault
Faulty temperature sensor in the heating flow pipe
The boilers that show this code
What our technician checks
- The flow temperature sensor's connector and cable
- The flow temperature sensor, replaced if needed
- The multi-pin connector on the circuit board
- The wiring harness, for a break
- The circuit board