Bulex Fault code Bulex
F.24

Temperature rising too fast

Breakdown: the boiler is stopped

Water circulates poorly in the boiler: the temperature rises too fast (dotted-code boilers), or the water coming back from the heating is too hot, above 90 °C (older ThermoMaster F and ThermoMaster HR TOP); the cause is for example the pump, air, lack of water or a stuck non-return valve. It is a safety shutdown: the boiler stops to protect itself.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Check the water pressure on the display or the gauge. Too low? Top up with water, as your installer showed you.
  3. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show F.24?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F.24

The meaning depends on the boiler: find yours below.

F.024

The temperature is rising too quickly

Breakdown: the boiler is stopped Isotwin Condens CS/1, Thema Condens CS/1
F.24

Safety shutdown: temperature rising too quickly

Breakdown: the boiler is stopped Isotwin Condens, Thema Condens
F.24

Safety cut-out: temperature rise too fast

Breakdown: the boiler is stopped Thema Condens F AS 45/65
F.24

Safety shutdown: temperature rise too fast

Breakdown: the boiler is stopped Thema Condens AS 48/65, Thema Condens F AS 80, ThemaClassic C30, Thematek C 18/24-LC/1, Thermomaster
F24

Water circulation fault

Breakdown: the boiler is stopped Isotwin Condens F, Thema Condens F
F24

Heating return temperature too high

Breakdown: the boiler is stopped Thermomaster F
F24

Return temperature > 90°C

Breakdown: the boiler is stopped Thermomaster HR TOP

The boilers that show this code

What our technician checks

  • The pump: operation and output
  • Bleeding the system
  • The system pressure
  • The non-return valve: operation and fitting direction
  • The flow and return isolating valves being open
  • ThermoMaster HR TOP: the system resistance and the bypass