Bulex Fault code Bulex
F.01

Return sensor fault or ignition fault

Breakdown: the boiler is stopped

On Bulex boilers whose code has a dot (F.01, F.001: Thema Condens, IsoTwin Condens, ThemaClassic, ThemaTek, ThermoMaster -A) and on the Thema Condens F and IsoTwin Condens F (F01), the boiler no longer receives the signal from its return temperature sensor. On the older ThermoMaster F, ThermoMaster HR TOP, Thema Condens F 24/30, Isotwin and Isomax (F1 without a dot), it is an ignition fault: the burner does not light, for example for lack of gas, and the boiler goes into safety mode.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Older boiler (F1 without a dot): check that the boiler's gas tap is open.
  3. Reset the boiler once only.
  4. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show F.01?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F.01

The meaning depends on the boiler: find yours below.

F.001

The return temperature sensor signal is interrupted

Breakdown: the boiler is stopped Isotwin Condens CS/1, Thema Condens CS/1
F.01

Return sensor open circuit

Breakdown: the boiler is stopped Isotwin Condens, Thema Condens
F.01

Return temperature sensor open circuit

Breakdown: the boiler is stopped Thema Condens AS 48/65, Thema Condens F AS 80, ThemaClassic C30, Thematek C 18/24-LC/1
F.01

Fault: return temperature sensor

Breakdown: the boiler is stopped Thermomaster
F.1

Return temperature sensor open circuit

Breakdown: the boiler is stopped Thema Condens F AS 45/65
F01

Heating return temperature sensor fault

Breakdown: the boiler is stopped Isotwin Condens F, Thema Condens F
F1

Ignition fault: flame loss during operation

Breakdown: the boiler is stopped Thermomaster F
F1

Ignition fault

Breakdown: the boiler is stopped Isotwin, Thema Condens F 24/30, Thermomaster HR TOP
F1

In the event of a gas supply interruption

Breakdown: the boiler is stopped Isotwin-Isomax

The boilers that show this code

What our technician checks

  • Dotted-code boilers: the return temperature sensor, its connector and cable
  • Dotted-code boilers: the multi-pin connector and the wiring harness
  • Older boilers: the gas supply, the gas tap and the gas pressure
  • Older boilers: the gas valve setting
  • Older boilers: the igniter, the ignition electrode and their wiring
  • Older boilers: the electrodes (position, corrosion) and the burner's cleanliness

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.