Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Bulex Fault code Bulex
F.13

Cylinder sensor short or main board fault

Breakdown: the boiler is stopped

On the dotted Bulex boilers (F.13, F.013) and on the IsoTwin Condens F (F13), the hot water cylinder's temperature sensor is short-circuited. On the older ThermoMaster F, Thema Condens F 24/30 and Isotwin (F13 without a dot), it is a main board fault (power supply, gas valve control or closing, memory, board overheating), and on the ThermoMaster HR TOP a wrong cylinder code; in every case a technician is needed.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show F.13?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F.13

The meaning depends on the boiler: find yours below.

F.013

The storage temperature sensor is short-circuited

Breakdown: the boiler is stopped Isotwin Condens CS/1, Thema Condens CS/1
F.13

Cylinder sensor short circuit

Breakdown: the boiler is stopped Isotwin Condens, Thema Condens, Thema Condens F AS 45/65
F.13

Cylinder temperature sensor short circuit

Breakdown: the boiler is stopped Thema Condens AS 48/65, ThemaClassic C30
F.13

Short circuit: domestic hot water cylinder temperature sensor

Breakdown: the boiler is stopped Thermomaster
F.13

Storage temperature sensor short circuit

Breakdown: the boiler is stopped Thematek C 18/24-LC/1
F13

Cylinder temperature sensor fault

Breakdown: the boiler is stopped Isotwin Condens F
F13

Main board fault

Breakdown: the boiler is stopped Isotwin, Thema Condens F 24/30, Thermomaster F
F13

- Wrong boiler code

Breakdown: the boiler is stopped Thermomaster HR TOP

The boilers that show this code

What our technician checks

  • Dotted-code boilers: the cylinder sensor, replaced if needed
  • Dotted-code boilers: the connecting cable and the wiring harness
  • Dotted-code boilers: the earth, the connector and the circuit board
  • Older boilers: every main board connection
  • Older boilers: the electronic board and the product code
  • ThermoMaster HR TOP: the cylinder parameter, then the main board

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.