Ignition failure or sensor mismatch

Breakdown: the boiler is stopped

On almost every Bulex boiler (F.28, F.028, and F28 on the Thema Condens F and IsoTwin Condens F), the boiler tried several times to light its burner without sensing a flame, for example a closed gas tap or too low a gas pressure: it goes into fault mode and stops heating. On the older ThermoMaster F, Thema Condens F 24/30 and Isotwin (F28 without a dot), F28 instead means a lasting mismatch between the flow and return sensors, which no longer agree.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Check that the boiler's gas tap is open.
  3. Code without a dot on a ThermoMaster F or a Thema Condens F 24/30: do not reset, call us.
  4. Reset the boiler once only.
  5. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show F.28?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F.28

The meaning depends on the boiler: find yours below.

F.028

The flame signal was not detected during the ignition phase

Breakdown: the boiler is stopped Isotwin Condens CS/1, Thema Condens CS/1
F.28

Start-up fault: ignition failed

Breakdown: the boiler is stopped Isotwin Condens, Thema Condens, Thema Condens F AS 80
F.28

Start-up failure: ignition unsuccessful

Breakdown: the boiler is stopped Thema Condens F AS 45/65
F.28

Ignition failed

Breakdown: the boiler is stopped Thema Condens AS 48/65, ThemaClassic C30, Thematek C 18/24-LC/1, Thematek C25
F.28

Fault: ignition failed at start-up

Breakdown: the boiler is stopped Thermomaster
F28

Ignition fault

Breakdown: the boiler is stopped Isotwin Condens F, Thema Condens F
F28

Permanent temperature difference between the heating flow and return sensors

Breakdown: the boiler is stopped Isotwin, Thema Condens F 24/30, Thermomaster F

The boilers that show this code

What our technician checks

  • The gas tap and the dynamic gas pressure
  • The thermal shut-off device, the flue and the air intake
  • The condensate drain
  • The gas valve and its setting
  • The ignition electrode and the igniter
  • The control electrode (gap to the burner), its cable and plug
  • The earth, the harness and the circuit board
  • Older boilers: the flow and return sensor connections