Ignition failure or sensor mismatch
Breakdown: the boiler is stopped
On almost every Bulex boiler (F.28, F.028, and F28 on the Thema Condens F and IsoTwin Condens F), the boiler tried several times to light its burner without sensing a flame, for example a closed gas tap or too low a gas pressure: it goes into fault mode and stops heating. On the older ThermoMaster F, Thema Condens F 24/30 and Isotwin (F28 without a dot), F28 instead means a lasting mismatch between the flow and return sensors, which no longer agree.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check that the boiler's gas tap is open.
- Code without a dot on a ThermoMaster F or a Thema Condens F 24/30: do not reset, call us.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show F.28?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.28
The meaning depends on the boiler: find yours below.
The flame signal was not detected during the ignition phase
Start-up fault: ignition failed
Start-up failure: ignition unsuccessful
Ignition failed
Fault: ignition failed at start-up
Ignition fault
Permanent temperature difference between the heating flow and return sensors
The boilers that show this code
What our technician checks
- The gas tap and the dynamic gas pressure
- The thermal shut-off device, the flue and the air intake
- The condensate drain
- The gas valve and its setting
- The ignition electrode and the igniter
- The control electrode (gap to the burner), its cable and plug
- The earth, the harness and the circuit board
- Older boilers: the flow and return sensor connections