Return sensor short or display link fault
Breakdown: the boiler is stopped
On the dotted Bulex boilers (F.11, F.011) and on the Thema Condens F and IsoTwin Condens F (F11), the return temperature sensor is short-circuited: faulty sensor or a cable touching earth. On the older ThermoMaster F, ThermoMaster HR TOP, Thema Condens F 24/30 and Isotwin (F11 without a dot), the main board and the control interface no longer communicate; in both cases it is a fault that needs a technician.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.11?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.11
The meaning depends on the boiler: find yours below.
The return temperature sensor is short-circuited
Return sensor short circuit
Return temperature sensor short circuit
Short circuit: return temperature sensor
Heating return temperature sensor fault
User interface board communication error
No signal at the main board
The boilers that show this code
What our technician checks
- Dotted-code boilers: the return sensor, replaced if needed
- Dotted-code boilers: the sensor cable and the wiring harness
- Dotted-code boilers: a short against the casing, and the circuit board
- Older boilers: the connections between the main board and the interface board
- ThermoMaster HR TOP: the wiring and the interface, replaced if the wiring is sound