Bulex Fault code Bulex
F.11

Return sensor short or display link fault

Breakdown: the boiler is stopped

On the dotted Bulex boilers (F.11, F.011) and on the Thema Condens F and IsoTwin Condens F (F11), the return temperature sensor is short-circuited: faulty sensor or a cable touching earth. On the older ThermoMaster F, ThermoMaster HR TOP, Thema Condens F 24/30 and Isotwin (F11 without a dot), the main board and the control interface no longer communicate; in both cases it is a fault that needs a technician.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show F.11?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F.11

The meaning depends on the boiler: find yours below.

F.011

The return temperature sensor is short-circuited

Breakdown: the boiler is stopped Isotwin Condens CS/1, Thema Condens CS/1
F.11

Return sensor short circuit

Breakdown: the boiler is stopped Isotwin Condens, Thema Condens
F.11

Return temperature sensor short circuit

Breakdown: the boiler is stopped Thema Condens AS 48/65, Thema Condens F AS 45/65, Thema Condens F AS 80, ThemaClassic C30, Thematek C 18/24-LC/1
F.11

Short circuit: return temperature sensor

Breakdown: the boiler is stopped Thermomaster
F11

Heating return temperature sensor fault

Breakdown: the boiler is stopped Isotwin Condens F, Thema Condens F
F11

User interface board communication error

Breakdown: the boiler is stopped Isotwin, Thema Condens F 24/30, Thermomaster F
F11

No signal at the main board

Breakdown: the boiler is stopped Thermomaster HR TOP

The boilers that show this code

What our technician checks

  • Dotted-code boilers: the return sensor, replaced if needed
  • Dotted-code boilers: the sensor cable and the wiring harness
  • Dotted-code boilers: a short against the casing, and the circuit board
  • Older boilers: the connections between the main board and the interface board
  • ThermoMaster HR TOP: the wiring and the interface, replaced if the wiring is sound