Bulex Fault code Bulex
F.20

Overheating or incompatible interface

Breakdown: the boiler is stopped

On the dotted Bulex boilers (F.20, F.020) and on the Thema Condens F and IsoTwin Condens F (F20), the overheat safety device has cut the gas: the water exceeded the maximum temperature, or a sensor or a loose contact tripped it; it is a safety shutdown. On the older ThermoMaster F, Thema Condens F 24/30 and Isotwin (F20 without a dot), the control interface and the main board do not recognise each other (wrong product code or wrong board); in both cases a technician is needed.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show F.20?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F.20

The meaning depends on the boiler: find yours below.

F.020

The safety temperature limiter (STB) has cut off the gas valve control

Breakdown: the boiler is stopped Isotwin Condens CS/1, Thema Condens CS/1
F.20

Safety shutdown: temperature limiter

Breakdown: the boiler is stopped Isotwin Condens, Thema Condens, Thema Condens F AS 80
F.20

Safety temperature limiter

Breakdown: the boiler is stopped Thema Condens F AS 45/65
F.20

Safety shutdown: overheat safety device

Breakdown: the boiler is stopped Thema Condens AS 48/65, ThemaClassic C30, Thematek C 18/24-LC/1
F.20

Safety shutdown: overheating temperature reached

Breakdown: the boiler is stopped Thermomaster
F20

Overheating fault

Breakdown: the boiler is stopped Isotwin Condens F, Thema Condens F
F20

Communication error between the user interface and the main board

Breakdown: the boiler is stopped Thermomaster F
F20

User interface incompatible with the main board

Breakdown: the boiler is stopped Isotwin, Thema Condens F 24/30

The boilers that show this code

What our technician checks

  • Dotted-code boilers: the flow and return sensors (loose contact, thermal contact)
  • Dotted-code boilers: the earth connection
  • Dotted-code boilers: the ignition cable, connector and electrode
  • Thema Condens F, IsoTwin Condens F: the pump and the isolating valves being open
  • Older boilers: the product code and the board reference
  • ThermoMaster F: the interface properly seated