Bulex Fault code Bulex
F.22

Not enough water or pressure too high

Breakdown: the boiler is stopped

On the dotted Bulex boilers (F.22, F.022) and on the Thema Condens F and IsoTwin Condens F (F22), the boiler has no water or not enough: the system pressure is too low, or the boiler no longer measures it correctly; it is a safety shutdown, so as not to fire dry. On the older ThermoMaster F and ThermoMaster HR TOP (F22 without a dot), it is the opposite: there is too much water, the system pressure is too high.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. ThermoMaster F or ThermoMaster HR TOP (F22 without a dot): the pressure is too high instead. Do not add water, do not reset, and call us.
  3. Check the water pressure on the display or the gauge. Too low? Top up with water, as your installer showed you.
  4. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show F.22?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F.22

The meaning depends on the boiler: find yours below.

F.022

There is no water or not enough water in the product, or the water pressure is too…

Breakdown: the boiler is stopped Isotwin Condens CS/1, Thema Condens CS/1
F.22

Safety shutdown: lack of water

Breakdown: the boiler is stopped Isotwin Condens, Thema Condens, Thema Condens AS 48/65, Thema Condens F AS 80, ThemaClassic C30, Thematek C 18/24-LC/1
F.22

Safety cut-out: lack of water

Breakdown: the boiler is stopped Thema Condens F AS 45/65
F.22

Safety shutdown: lack of water in the boiler

Breakdown: the boiler is stopped Thermomaster
F22

Lack of water in the installation (pressure < 0.3 bar)

Breakdown: the boiler is stopped Isotwin Condens F, Thema Condens F
F22

Too much water in the installation

Breakdown: the boiler is stopped Thermomaster F
F22

System water pressure too high

Breakdown: the boiler is stopped Thermomaster HR TOP

The boilers that show this code

What our technician checks

  • Filling the system and bleeding it
  • The water pressure sensor
  • The cable to the pump and to the pressure sensor, and the harness
  • The automatic filling loop and the internal expansion vessel
  • Thema Condens F, IsoTwin Condens F: the supply valve, the pump, leaks
  • ThermoMaster HR TOP: the expansion vessel, then lowering the pressure

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.