Bulex Fault code Bulex
F.49

eBUS line fault (controls)

Breakdown: the boiler is stopped

The eBUS line, which links the boiler to its thermostat and modules, has a voltage problem: short circuit, overload or two power supplies with different polarities. This is a fault: the boiler stops and our technician has to find the cause before putting it back into service.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show F.49?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F.49

The meaning depends on the boiler: find yours below.

F.049

The eBUS line is short-circuited or there are two active eBUS sources whose…

Breakdown: the boiler is stopped Isotwin Condens CS/1, Thema Condens CS/1
F.49

eBUS fault

Breakdown: the boiler is stopped Isotwin Condens, Thema Condens, Thema Condens AS 48/65, Thema Condens F AS 45/65, Thema Condens F AS 80, ThemaClassic C30, Thematek C 18/24-LC/1
F.49

eBus fault: low voltage

Breakdown: the boiler is stopped Thermomaster
F49

EBUS voltage fault

Breakdown: the boiler is stopped Isotwin Condens F, Thema Condens F

The boilers that show this code

What our technician checks

  • The eBUS connections: short circuit and overload
  • The polarity (+/-) of the power supplies on the eBUS
  • The load and voltage on the eBUS line

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.