Bulex Fault code Bulex
S.54

Waiting time: water shortage, temperature rising too fast

Blocking: it retries by itself

The boiler detects a water shortage, most often because the water temperature rises too fast: it blocks the burner for a waiting time, up to 20 minutes on some models. It then restarts by itself, but if the code comes back, the water pressure of the system must be checked.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Check the water pressure (display or gauge): below 0.8 bar, top up the heating water as your installer showed you.
  3. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show S.54?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code S.54

The meaning depends on the boiler: find yours below.

S.054

The appliance is waiting due to lack of water

Blocking: it retries by itself Isotwin Condens CS/1, Thema Condens CS/1
S.54

Product waiting for the safety function due to lack of water…

Blocking: it retries by itself Isotwin Condens, Thema Condens, Thema Condens F AS 80
S.54

Waiting cycle: lack of water in the installation / temperature difference between the flow…

Blocking: it retries by itself Isotwin Condens F, Thema Condens F
S.54

The appliance is in the waiting time of the blocking function for…

Blocking: it retries by itself Thema Condens F AS 45/65
S.54

Product in waiting time by the safety shutdown function due to a lack of water…

Blocking: it retries by itself Thema Condens AS 48/65
S.54

Waiting period: lack of water in the circuit (difference between flow and…

Blocking: it retries by itself Thermomaster
S.54

Waiting time: no water in the circuit, temperature of the temperature sensor…

Blocking: it retries by itself Thermomaster F
S.54

Product waiting for modulation lock/safety function due to…

Blocking: it retries by itself Thematek C 18/24-LC/1
S.54

Waiting time: no water in the system, temperature rise of the…sensor

Blocking: it retries by itself ThemaClassic C30

The boilers that show this code

What our technician checks

  • The system pressure
  • Air in the circuit and the internal air vent
  • The heating pump, its cable and connector
  • The non-return valve