Gas valve control fault
Breakdown: the boiler is stopped
The circuit board cannot drive the gas valve: valve cable short-circuited or earthed, valve coils faulty, or circuit board faulty. This is a fault: the boiler stops and our technician has to find the cause before putting it back into service.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.61?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.61
The meaning depends on the boiler: find yours below.
The ASIC or the μController is not operating within the allotted time
Fuel control valve fault
Fuel valve control fault
Gas valve control fault
Gas safety valve control fault
Fault: gas valve control
Main board faulty
The boilers that show this code
What our technician checks
- The wiring harness to the gas valve (short circuit, earth fault)
- The gas valve plug
- The gas valve coils, valve replaced if faulty
- The circuit board, replaced if faulty
- The main board connections, the board and the product code