Implausible flame signal
Breakdown: the boiler is stopped
The circuit that monitors the flame sends an inconsistent signal: the flame monitor on the circuit board is at fault, and on some models the flue gas path. This is a fault: the boiler stops and our technician has to find the cause before putting it back into service.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.67?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.67
The meaning depends on the boiler: find yours below.
The flame monitor is faulty
Electronics/flame fault
Flame plausibility error
Incorrect value returned by the ASIC (flame signal)
Main board faulty
The boilers that show this code
What our technician checks
- The flame signal
- The wiring harness and the flame monitor
- The whole flue gas path
- The circuit board, replaced if faulty
- The main board connections, the board and the product code