Flame lost during operation, relighting failed
Breakdown: the boiler is stopped
The flame went out while the boiler was heating and the relighting attempts failed, for example the gas was cut off for a moment, flue gas recirculating to the air intake, a blocked condensate drain or a poor earth: the boiler goes into fault mode and stops heating. The one exception is the older Thema Condens F 24/30, where F29 points to the heat exchanger's thermal fuse.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check that the boiler's gas tap is open.
- Code without a dot on a Thema Condens F 24/30: do not reset, call us.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show F.29?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.29
The meaning depends on the boiler: find yours below.
The ignition attempt after flame loss during operation failed
Operating fault: ignition failed
Failure during operation: re-ignition unsuccessful
Fault during operation: re-ignition failed
Ignition and monitoring fault during operation - flame loss
Fault: flame loss
Flame goes out during operation
Thermal fuse fault
The boilers that show this code
What our technician checks
- The gas supply
- The flue: recirculation or blockage
- The condensate drain
- The appliance earth
- The ignition transformer and the igniter
- The control electrode (gap to the burner, corrosion)
- The gas valve and the air-gas ratio
- Thema Condens F 24/30: the heat exchanger, to be replaced