Bulex Fault code Bulex
F.27

Flame detected with the burner off

Breakdown: the boiler is stopped

The boiler sees a flame signal while the burner is off and the gas valve closed: a leaking gas valve, moisture or a fault on the circuit board, or a faulty electrode; it is a safety shutdown. The one exception is the older ThermoMaster F, where F27 points to the vortex (flow) sensor, disconnected or faulty; in both cases a technician is needed.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show F.27?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F.27

The meaning depends on the boiler: find yours below.

F.027

A flame signal has been detected while the burner is off

Breakdown: the boiler is stopped Isotwin Condens CS/1, Thema Condens CS/1
F.27

Safety shutdown: flame simulation

Breakdown: the boiler is stopped Isotwin Condens, Thema Condens, Thema Condens AS 48/65, Thema Condens F AS 45/65, Thema Condens F AS 80, ThemaClassic C30, Thematek C 18/24-LC/1
F.27

Safety shutdown: flame detection fault

Breakdown: the boiler is stopped Thermomaster
F27

Flame detection fault

Breakdown: the boiler is stopped Isotwin Condens F, Thema Condens F
F27

Vortex sensor fault

Breakdown: the boiler is stopped Thermomaster F

The boilers that show this code

What our technician checks

  • The gas solenoid valve: tightness and operation
  • The circuit board (moisture), replaced if needed
  • The flame monitor
  • The monitoring or flame-sensing electrode
  • Thema Condens F, IsoTwin Condens F: the main board and the igniter
  • ThermoMaster F: the vortex sensor and its connection