Flame detected with the burner off
Breakdown: the boiler is stopped
The boiler sees a flame signal while the burner is off and the gas valve closed: a leaking gas valve, moisture or a fault on the circuit board, or a faulty electrode; it is a safety shutdown. The one exception is the older ThermoMaster F, where F27 points to the vortex (flow) sensor, disconnected or faulty; in both cases a technician is needed.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.27?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.27
The meaning depends on the boiler: find yours below.
A flame signal has been detected while the burner is off
Safety shutdown: flame simulation
Safety shutdown: flame detection fault
Flame detection fault
Vortex sensor fault
The boilers that show this code
What our technician checks
- The gas solenoid valve: tightness and operation
- The circuit board (moisture), replaced if needed
- The flame monitor
- The monitoring or flame-sensing electrode
- Thema Condens F, IsoTwin Condens F: the main board and the igniter
- ThermoMaster F: the vortex sensor and its connection