Bulex Fault code Bulex
S.53

Waiting time due to water shortage

Blocking: it retries by itself

The boiler measures too large a gap between the water leaving for the heating and the water coming back, a sign of water shortage: it limits its power or blocks the burner for a waiting time. It then restarts by itself, but if the code comes back, the water pressure of the system must be checked.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Check the water pressure (display or gauge): below 0.8 bar, top up the heating water as your installer showed you.
  3. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show S.53?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code S.53

The meaning depends on the boiler: find yours below.

S.53

Product in waiting time of the modulation block/safety shutdown function due to…

Blocking: it retries by itself Isotwin Condens, Thema Condens
S.53

Waiting cycle: temperature difference between the flow pipe and the return pipe of the…

Blocking: it retries by itself Isotwin Condens F, Thema Condens F
S.53

The appliance is in the waiting time of the modulation lock / function…

Blocking: it retries by itself Thema Condens F AS 45/65
S.53

Product waiting for modulation lock/safety function due to…

Blocking: it retries by itself Thema Condens F AS 80, ThemaClassic C30, Thematek C 18/24-LC/1
S.53

Modulation blocked by the safety function due to a lack…

Blocking: it retries by itself Thema Condens AS 48/65
S.53

Product waiting / safety shutdown due to lack of water (difference between…

Blocking: it retries by itself Thermomaster
S.53

Waiting time: no water in the circuit, the temperature difference between the…

Blocking: it retries by itself Thermomaster F

The boilers that show this code

What our technician checks

  • The water pressure and filling of the system
  • Air in the system, to be purged
  • The heating pump, its cable and connector
  • The flow and return sensors, not swapped
  • The strainer of the hydraulic block