Invalid boiler identification
Breakdown: the boiler is stopped
The circuit board and the display do not recognise the boiler model: the device identification (DSN) or the coding resistor is missing or does not match, for example after the board and the display were replaced at the same time. This is a fault: the boiler stops and our technician has to find the cause before putting it back into service.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.70?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.70
The meaning depends on the boiler: find yours below.
The appliance reference (DSN) is missing, incorrect or incompatible with the…
Fault: incorrect appliance coding
Invalid appliance identification
Appliance identification (DSN) invalid
Invalid product code (DSN)
User interface not compatible with the main board
The boilers that show this code
What our technician checks
- The device identification (DSN), to be set under d.93
- The product code shown, compared with the one on the rating plate
- The power-rating coding resistor
- The wiring harness (break)
- The circuit board reference