Gas valve or flue fault
Breakdown: the boiler is stopped
On a Vitodens 200-W, 222-F, 222-W or 300-W, the gas valve is faulty, its modulation valve is wrongly controlled or the flue is blocked: it is a fault that locks the burner out for safety, and the boiler only starts again after a reset. On a Vitodens 100-W (B1HC, B1HA, WB1C, WB1B), FC means a faulty electrical fan control or, on the WB1B, a faulty controller or boiler coding plug: the burner stays blocked until the fault is repaired.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- On a Vitodens 100-W (B1HC, B1HA, WB1C, WB1B), do not reset the boiler: call us if the code stays on or comes back.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show FC?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code FC
The meaning depends on the boiler: find yours below.
Electrical control of the fan (control unit) defective
Control unit or boiler coding card defective
Gas combination valve defective, modulation valve control incorrect or flue gas path obstructed
What our technician checks
- The combined gas valve and its connecting cables
- The flue: blockage or narrowing
- Vitodens 100-W: the fan's connecting cable, replaced if needed, otherwise the controller
- Vitodens 100-W WB1B: the boiler coding plug or the controller, to be replaced