Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Viessmann Fault code Viessmann
38

Boiler temperature sensor circuit broken

Blocking: it retries by itself

The boiler temperature sensor, which measures the water temperature inside the boiler, gives no reading any more: its circuit is broken. On a Vitodens, the burner stays blocked and the boiler stops heating until the sensor is repaired; on the floor-standing boilers with a Vitotronic control (KC2B, KO1B, KW1, KW2, KW3) it keeps heating in emergency mode, controlled by its boiler thermostat or held at the hot water temperature.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show 38?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code 38

The meaning depends on the boiler: find yours below.

38

Open circuit of the boiler temperature sensor

Blocking: it retries by itself Vitodens 100-W B1HA, Vitodens 100-W B1HC, Vitodens 100-W WB1C, Vitodens 200-W B2HA, Vitodens 200-W B2HB, Vitodens 200-W WB2C, Vitodens 222-F B2SA, Vitodens 222-F B2SB, Vitodens 222-F B2TA, Vitodens 222-F B2TB, Vitodens 222-F FR2B, Vitodens 222-F FS2B, Vitodens 222-W B2LA, Vitodens 222-W B2LB, Vitodens 222-W WS2B, Vitodens 300-W B3HA, Vitodens 300-W B3HB, Vitotronic 100 KC2B, Vitotronic 200 KO1B
38

Open circuit of the boiler sensor

Blocking: it retries by itself Vitodens 100-W WB1A, Vitodens 100-W WB1B, Vitodens 200 WB2A, Vitodens 200-W WB2B, Vitodens 222-F FS2A, Vitodens 222-W WS2A
38

Open circuit Boiler sensor

Blocking: it retries by itself Vitotronic 200 KW1
38

Open circuit boiler sensor

Blocking: it retries by itself Vitotronic 200 KW2, Vitotronic 300 KW3

What our technician checks

  • The boiler temperature sensor
  • The sensor's resistance, compared with the curve; sensor replaced if it differs widely, after draining the boiler on the heating side (the sensor sits in the water)

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.