Viessmann Fault code Viessmann
10

Outdoor temperature sensor short-circuited

Blocking: it retries by itself

The outdoor temperature sensor, which measures the outside temperature to control the heating, or its cable is short-circuited. The boiler keeps heating without this reading: a Vitodens 100-W (B1HC, B1HA, WB1C, WB1B, WB1A) switches to constant-temperature operation, the Vitodens 200, 222-F, 222-W and 300-W and the floor-standing boilers with a Vitotronic 200 or 300 control (KO1B, KW1, KW2, KW3) control the heating as if it were 0 °C outside, and our technician needs to check the sensor.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show 10?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code 10

The meaning depends on the boiler: find yours below.

10

Short circuit of the outside temperature sensor

Blocking: it retries by itself Vitodens 100-W B1HA, Vitodens 100-W B1HC, Vitodens 100-W WB1C, Vitodens 200-W B2HA, Vitodens 200-W B2HB, Vitodens 200-W WB2C, Vitodens 222-F B2SA, Vitodens 222-F B2SB, Vitodens 222-F B2TA, Vitodens 222-F B2TB, Vitodens 222-F FR2B, Vitodens 222-F FS2B, Vitodens 222-W B2LA, Vitodens 222-W B2LB, Vitodens 222-W WS2B, Vitodens 300-W B3HA, Vitodens 300-W B3HB, Vitotronic 200 KO1B
10

Short circuit of the outside sensor

Blocking: it retries by itself Vitodens 100-W WB1A, Vitodens 100-W WB1B, Vitodens 200 WB2A, Vitodens 200-W WB2B, Vitodens 222-F FS2A, Vitodens 222-W WS2A
10

Short circuit Outside sensor

Blocking: it retries by itself Vitotronic 200 KW1
10

Short circuit outside sensor

Blocking: it retries by itself Vitotronic 200 KW2, Vitotronic 300 KW3

What our technician checks

  • The outdoor temperature sensor and its cable
  • The sensor's resistance (NTC 10 kΩ), measured and compared with the curve; sensor or cable replaced depending on the result

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.