Boiler temperature sensor short-circuited
Blocking: it retries by itself
The boiler temperature sensor, which measures the water temperature inside the boiler, is short-circuited; on a Vitodens 100-W B1HF, 30 refers to another sensor, the one on the system's low loss header. On the other Vitodens, the burner stays blocked and the boiler stops heating until the sensor is repaired; on the floor-standing boilers with a Vitotronic control (KC2B, KO1B, KW1, KW2, KW3) it keeps heating in emergency mode, controlled by its boiler thermostat or held at the hot water temperature, and the B1HF carries on without the low loss header sensor.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show 30?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 30
The meaning depends on the boiler: find yours below.
Short circuit of the boiler temperature sensor
Short circuit of the boiler sensor
Short circuit of the low loss header sensor
Short circuit Boiler sensor
Short circuit boiler sensor
What our technician checks
- The boiler temperature sensor
- The sensor's resistance, compared with the curve; sensor replaced if it differs widely, after draining the boiler on the heating side (the sensor sits in the water)
- Vitodens 100-W B1HF: the low loss header flow sensor, and the voltage at its input on the electronics module (3.3 V with the sensor disconnected)