Hot water sensor circuit broken
Blocking: it retries by itself
The hot water temperature sensor (cylinder sensor, loading sensor or, depending on the model, comfort sensor) gives no reading any more: its circuit is broken; on a Vitodens 100-W B1HF, 58 means something else, a short circuit of the room temperature sensor. On the other Vitodens, the boiler no longer makes hot water until the sensor is repaired; on the floor-standing boilers with a Vitotronic control (KC2B, KO1B, KW1, KW2, KW3) the cylinder is still heated, at the boiler temperature and without hot water priority; the B1HF keeps heating without taking the room temperature into account.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show 58?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 58
The meaning depends on the boiler: find yours below.
Open circuit of the DHW temperature sensor
Open circuit of the DHW sensor
Open circuit of the DHW temperature sensor or of the comfort sensor
Open circuit of the DHW temperature sensor or the comfort temperature sensor
Open circuit of the DHW sensor or the comfort sensor
Open circuit of the charge temperature sensor
Short circuit of the room temperature sensor
Open circuit DHW sensor
Open circuit DHW sensor 1
What our technician checks
- The cylinder hot water temperature sensor (or its loading sensor)
- The comfort sensor, on the models that have one (Vitodens 200-W, 200 WB2A, 222-W B2LA and WS2B)
- The sensor's resistance, compared with the curve; sensor replaced if it differs widely
- Vitodens 100-W B1HF: the plug and cable of the external room temperature sensor; with no external sensor, the Vitotrol's control module replaced