Viessmann Fault code Viessmann
50

Hot water sensor short-circuited

Breakdown: the boiler is stopped

The hot water temperature sensor (cylinder sensor, loading sensor or, depending on the model, comfort sensor) is short-circuited; on a Vitodens 100-W B1HF, 50 refers to another sensor, the flue gas temperature sensor. On the other Vitodens, the boiler no longer makes hot water until the sensor is repaired; on the floor-standing boilers with a Vitotronic control (KC2B, KO1B, KW1, KW2, KW3) the cylinder is still heated, at the boiler temperature and without hot water priority; on the B1HF the burner locks out and the boiler stops until it is reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Vitodens 100-W B1HF only: reset the boiler once only.
  3. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show 50?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code 50

The meaning depends on the boiler: find yours below.

50

Short circuit of the DHW temperature sensor

Blocking: it retries by itself Vitodens 100-W B1HA, Vitodens 100-W B1HC, Vitodens 100-W WB1C, Vitodens 222-F B2SA, Vitodens 222-F B2SB, Vitodens 222-F B2TA, Vitodens 222-F B2TB, Vitodens 222-F FR2B, Vitodens 222-F FS2B, Vitodens 222-W B2LB, Vitodens 300-W B3HA, Vitodens 300-W B3HB, Vitotronic 100 KC2B, Vitotronic 200 KO1B
50

Short circuit of the DHW sensor

Blocking: it retries by itself Vitodens 100-W WB1A, Vitodens 100-W WB1B, Vitodens 222-F FS2A
50

Short circuit of the DHW temperature sensor or of the comfort sensor

Blocking: it retries by itself Vitodens 200-W B2HB, Vitodens 222-W B2LA
50

Short circuit of the DHW temperature sensor or the comfort temperature sensor

Blocking: it retries by itself Vitodens 200-W B2HA, Vitodens 200-W WB2C, Vitodens 222-W WS2B
50

Short circuit of the DHW sensor or the comfort sensor

Blocking: it retries by itself Vitodens 200 WB2A, Vitodens 200-W WB2B
50

Short circuit of the charge temperature sensor

Blocking: it retries by itself Vitodens 222-W WS2A
50

Short circuit of the flue gas temperature sensor

Breakdown: the boiler is stopped Vitodens 100-W B1HF
50

Short circuit DHW sensor

Blocking: it retries by itself Vitotronic 200 KW1, Vitotronic 200 KW2
50

Short circuit DHW sensor 1

Blocking: it retries by itself Vitotronic 300 KW3

What our technician checks

  • The cylinder hot water temperature sensor (or its loading sensor)
  • The comfort sensor, on the models that have one (Vitodens 200-W, 200 WB2A, 222-W B2LA and WS2B)
  • The sensor's resistance, compared with the curve; sensor replaced if it differs widely
  • Vitodens 100-W B1HF: the flue gas temperature sensor, then unlocking the boiler