Viessmann Fault code Viessmann
18

Outdoor temperature sensor circuit broken

Blocking: it retries by itself

The outdoor temperature sensor, which measures the outside temperature to control the heating, gives no reading any more: its circuit is broken; on a Vitotronic 100 KC2B control, which runs at constant temperature, 18 rather means that a sensor was connected to the control by mistake. The boiler keeps heating: a Vitodens 100-W (B1HC, B1HA, WB1C, WB1B, WB1A) switches to constant-temperature operation, the Vitodens 200, 222-F, 222-W and 300-W and the floor-standing boilers with a Vitotronic 200 or 300 control heat as if it were 0 °C outside, the Vitotronic 100 KC2B runs normally, and our technician needs to check the sensor or the setting.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show 18?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code 18

The meaning depends on the boiler: find yours below.

18

Open circuit of the outside temperature sensor

Blocking: it retries by itself Vitodens 100-W B1HA, Vitodens 100-W B1HC, Vitodens 100-W WB1C, Vitodens 200-W B2HA, Vitodens 200-W B2HB, Vitodens 200-W WB2C, Vitodens 222-F B2SA, Vitodens 222-F B2SB, Vitodens 222-F B2TA, Vitodens 222-F B2TB, Vitodens 222-F FR2B, Vitodens 222-F FS2B, Vitodens 222-W B2LA, Vitodens 222-W B2LB, Vitodens 222-W WS2B, Vitodens 300-W B3HA, Vitodens 300-W B3HB, Vitotronic 200 KO1B
18

Open circuit of the outside sensor

Blocking: it retries by itself Vitodens 100-W WB1A, Vitodens 100-W WB1B, Vitodens 200 WB2A, Vitodens 200-W WB2B, Vitodens 222-F FS2A, Vitodens 222-W WS2A
18

A sensor has been inserted into the socket by mistake!

Blocking: it retries by itself Vitotronic 100 KC2B
18

Open circuit Outside sensor

Blocking: it retries by itself Vitotronic 200 KW1
18

Open circuit outside sensor

Blocking: it retries by itself Vitotronic 200 KW2, Vitotronic 300 KW3

What our technician checks

  • The outdoor temperature sensor and its cable
  • The sensor's resistance (NTC 10 kΩ), measured and compared with the curve; sensor or cable replaced depending on the result
  • Vitotronic 100 KC2B: coding 25:0 in group 1 « General »

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.