Gas valve not closing properly
Breakdown: the boiler is stopped
On every Vitodens except the One Base (100-W, 200, 200-W, 222-F, 222-W, 300-W), the burner's gas valve closes too late or does not close: it is a fault that locks the burner out for safety, and the boiler only starts again after a reset. On a Vitodens One Base (200-W B2HF or B2KF, 222-F B2TF, 222-W B2LF), F.8 means something else: the hot water temperature sensor is short-circuited and the boiler no longer makes domestic hot water.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- On a Vitodens One Base (code F.8), do not reset the boiler: call us if the code stays on or comes back.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show F8?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F8
The meaning depends on the boiler: find yours below.
Short circuit of the DHW temperature sensor
Delayed closing of the fuel valve
The fuel valve or the modulation valve does not close
What our technician checks
- The combined gas valve, replaced if needed
- Both control paths of the gas valve (except Vitodens 200-W B2HB, 222-F B2TB and B2SB, 222-W B2LB)
- Vitodens One Base: the hot water sensor connection (plug 5, terminals 3 and 4 on the HMU module), plugs, cables and corrosion
- Vitodens One Base: the hot water sensor's resistance (NTC 10 kΩ), sensor replaced if needed