Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Viessmann Fault code Viessmann
EF

Flame lost right after ignition

Breakdown: the boiler is stopped

The flame lights and then goes out straight away, during the start-up safety time: the cause is the gas supply or gas pressure, flue gases getting back into the combustion air, or the ionisation electrode. The burner goes into fault: the boiler stops heating and only starts again after a reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Check that the boiler's gas supply valve is open.
  3. Reset the boiler once only.
  4. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show EF?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code EF

The meaning depends on the boiler: find yours below.

EF

Loss of flame immediately after its formation (during the safety time)

Breakdown: the boiler is stopped Vitodens 200-W B2HA, Vitodens 200-W B2HB, Vitodens 200-W WB2C, Vitodens 222-F B2SA, Vitodens 222-F B2SB, Vitodens 222-F B2TA, Vitodens 222-F B2TB, Vitodens 222-F FR2B, Vitodens 222-W B2LA, Vitodens 222-W B2LB, Vitodens 222-W WS2B, Vitodens 300-W B3HA, Vitodens 300-W B3HB
EF

Flame lost directly after flame formation (during the safety time)

Breakdown: the boiler is stopped Vitodens 200-W WB2B, Vitodens 222-F FS2A
EF

Flame loss immediately after flame formation (during the safety time)

Breakdown: the boiler is stopped Vitodens 222-F FS2B

What our technician checks

  • The gas supply: gas pressure and gas flow monitor
  • Flue gas recirculation in the flue and air intake ducts
  • The ionisation electrode: distance to the burner grid and fouling, replaced if needed

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.