Viessmann Fault code Viessmann
20

Flow temperature sensor short-circuited

Blocking: it retries by itself

The sensor that measures the heating flow temperature is short-circuited: on a Vitodens 200, 200-W, 222-F, 222-W or 300-W it is the system sensor on the low-loss header; on a Vitotronic 200 KW2 or 300 KW3 control (floor-standing boilers) it is the one of the mixing valve circuit. The boiler does not stop: the Vitodens regulates without this sensor and the Vitotronic closes that circuit's mixing valve; it is a warning, for our technician to repair.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show 20?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code 20

The meaning depends on the boiler: find yours below.

20

Short circuit of the system flow temperature sensor

Blocking: it retries by itself Vitodens 200-W B2HB, Vitodens 200-W WB2C, Vitodens 222-F B2SA, Vitodens 222-F B2SB, Vitodens 222-F B2TA, Vitodens 222-F B2TB, Vitodens 222-F FR2B, Vitodens 222-F FS2B, Vitodens 222-W B2LA, Vitodens 222-W B2LB, Vitodens 222-W WS2B, Vitodens 300-W B3HA, Vitodens 300-W B3HB
20

Short circuit of the flow temperature sensor

Blocking: it retries by itself Vitodens 200-W B2HA
20

Short circuit of the system flow sensor

Blocking: it retries by itself Vitodens 200 WB2A, Vitodens 200-W WB2B, Vitodens 222-F FS2A, Vitodens 222-W WS2A
20

Short circuit flow sensor

Blocking: it retries by itself Vitotronic 200 KW2
20

Short circuit flow temperature sensor heating circuit M1

Blocking: it retries by itself Vitotronic 300 KW3

What our technician checks

  • The low-loss header temperature sensor (Vitodens)
  • The flow sensor of the mixing valve circuit (Vitotronic 200 KW2, 300 KW3)

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.