No flame when the burner starts

Breakdown: the boiler is stopped

When the burner starts, the boiler detects no flame, or a flame signal that is too weak: the cause is the gas supply or gas pressure, the gas valve, the ignition, the ionisation electrode or the condensate drain. The burner goes into fault: the boiler stops heating and only starts again after a reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Check that the boiler's gas supply valve is open.
  3. Reset the boiler once only.
  4. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show EE?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code EE

The meaning depends on the boiler: find yours below.

EE

The flame signal is absent or too weak when the burner starts

Breakdown: the boiler is stopped Vitodens 200-W B2HB, Vitodens 222-F B2SB, Vitodens 222-F B2TB, Vitodens 222-W B2LA, Vitodens 300-W B3HB
EE

Flame signal absent or too weak when the burner starts

Breakdown: the boiler is stopped Vitodens 200-W B2HA, Vitodens 200-W WB2B, Vitodens 200-W WB2C, Vitodens 222-F B2SA, Vitodens 222-F B2TA, Vitodens 222-F FR2B, Vitodens 222-W B2LB, Vitodens 222-W WS2B, Vitodens 300-W B3HA
EE

Flame signal absent or too weak at burner start

Breakdown: the boiler is stopped Vitodens 222-F FS2B
EE

Flame signal unavailable or too weak at burner start

Breakdown: the boiler is stopped Vitodens 222-F FS2A

What our technician checks

  • The gas supply: gas pressure and gas flow monitor
  • Air in the gas line, common at first start-up
  • The combined gas valve and its 230 V control signal
  • The ignition unit and its 230 V control signal (plugs X2.1 and X2.2)
  • The ignition electrode: cables to the ignition unit, gap, fouling and insulation
  • The ionisation electrode, its connecting cable and the measured ionisation current
  • The condensate drain and condensate build-up (remove the fan unit before the burner)