Error during combustion calibration
Breakdown: the boiler is stopped
On a Vitodens 200-W WB2B, 222-F FS2A or 222-W WS2A, the flame signal (ionisation current) went outside the allowed range during the automatic calibration of the combustion; on the other Vitodens 200-W, 222-F, 222-W and 300-W, the control hit a parameter error during that calibration. The burner goes into fault: the boiler stops heating and only starts again after a reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show EC?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code EC
The meaning depends on the boiler: find yours below.
Parameter setting fault during calibration
Ionisation current outside the valid range during calibration
What our technician checks
- The boiler coding plug, to be replaced if a reset is not enough
- The ionisation electrode and its cable (Vitodens 200-W WB2B, 222-F FS2A, 222-W WS2A)