Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Viessmann Fault code Viessmann
Eb

Combustion calibration interrupted

Breakdown: the boiler is stopped

On a Vitodens 200-W B2HB, 222-F B2TB or B2SB and 222-W B2LB, the boiler shut down on a process fault during the automatic calibration of its combustion; on a Vitodens 200-W WB2B or 222-W WS2A, it repeatedly could not get rid of enough heat during that calibration; on the other Vitodens 200-W, 222-F, 222-W and 300-W, the flame went out several times during the calibration. In every case the burner goes into fault: the boiler stops heating and only starts again after a reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Check that the boiler's gas supply valve is open.
  3. On a Vitodens 200-W WB2B or 222-W WS2A: check that the thermostatic radiator valves are open, so that the boiler can pass on its heat.
  4. Reset the boiler once only.
  5. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show Eb?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code Eb

The meaning depends on the boiler: find yours below.

Eb

Malfunction, shutdown during calibration

Breakdown: the boiler is stopped Vitodens 200-W B2HB
Eb

Flame lost several times during calibration

Breakdown: the boiler is stopped Vitodens 200-W B2HA, Vitodens 200-W WB2C, Vitodens 222-F B2SA, Vitodens 222-F B2TA, Vitodens 222-F FR2B, Vitodens 222-W B2LA, Vitodens 222-W WS2B, Vitodens 300-W B3HA
Eb

Heat dissipation repeatedly too low during calibration

Breakdown: the boiler is stopped Vitodens 200-W WB2B, Vitodens 222-W WS2A
Eb

Shut-off malfunction during calibration

Breakdown: the boiler is stopped Vitodens 222-F B2SB, Vitodens 222-F B2TB
Eb

Repeated flame loss during calibration

Breakdown: the boiler is stopped Vitodens 222-F FS2B
Eb

Process error Shutdown during calibration

Breakdown: the boiler is stopped Vitodens 222-W B2LB
Eb

Repeated loss of flame during calibration

Breakdown: the boiler is stopped Vitodens 300-W B3HB

What our technician checks

  • Condensate build-up in the system, to be cleared (remove the fan unit before the burner)
  • The gas supply pressure and the inlet strainer of the combined gas valve
  • The ionisation electrode: fouling and distance to the burner grid
  • The gas type assignment
  • The flue system, and any flue gas recirculation to be removed
  • The internal extension H1 and the devices connected to it (plug 53/96, power interruption)
  • The cable to the fan unit and the free running of the fan wheel
  • Heat take-off during calibration (Vitodens 200-W WB2B and 222-W WS2A; on the WB2B, coding address 12:1)