Flame loss or abnormal flame signal during calibration
Breakdown: the boiler is stopped
On a Vitodens 200-W B2HB, 222-F B2TB or B2SB and 222-W B2LB, the flame went out several times during the automatic calibration of the combustion; on a Vitodens 200-W WB2B, 222-F FS2A or 222-W WS2A, the flame signal (ionisation current) went outside the allowed range during that calibration. In both cases the burner goes into fault: the boiler stops heating and only starts again after a reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
- Keep paint, solvent and cleaning product fumes, and building dust, away from the boiler.
Does your boiler show E9?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code E9
The meaning depends on the boiler: find yours below.
Repeated loss of flame during calibration
Ionisation current outside the valid range during calibration
What our technician checks
- The ionisation electrode and its connecting cable
- The plug connections (loose contacts)
- The flue system: tightness and flue gas recirculation
- Condensate build-up in the system (remove the fan unit before the burner)
- The inlet of the combined gas valve and its strainer (fouling)
- The source of deposits on the electrodes in the boiler room and flue system (detergents, cleaning or personal care products)
- After replacing the burner grid and the electrode: cleaning the fan unit, the gas-air duct and the Venturi extension