Water pressure too low
Breakdown: the boiler is stopped
On a Vitodens 100-W (WB1B, WB1A), 222-F (B2SB, B2TA, B2SA, FR2B) or 300-W B3HA, the water pressure of the heating system is too low: the burner stays blocked until the pressure is restored. On a Vitodens 200 WB2A, E6 means a blocked flue or air intake: it is a fault that locks the burner out for safety, and the boiler only starts again after a reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check the water pressure on the boiler's gauge: at least 1 bar (0.8 bar on a Vitodens 100-W). Too low? Top up with water as your installer showed you, or call us.
- Does the code stay on or come back? Do not take anything apart: call us.
- On a Vitodens 200 WB2A (blocked flue or air intake): reset the boiler once only; if the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show E6?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.