Safety chain fault or heat not drawn off
Breakdown: the boiler is stopped
On a Vitodens 100-W B1HC, B1HA or WB1C, E3 means a fault in the safety chain (the temperature limiter, its cables or the control); on a Vitodens 200-W, 222-F, 222-W or 300-W, it means the boiler could not give off enough heat to the system during its calibration and its monitoring thermostat cut out. In both cases the boiler locks out and only starts again after a reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- On a Vitodens 200-W, 222-F, 222-W or 300-W, open the thermostatic valves of the radiators so that the boiler can give off its heat.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show E3?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code E3
The meaning depends on the boiler: find yours below.
Fault in the safety chain
Heat dissipation too low during calibration
What our technician checks
- The temperature limiter and its connecting cables (Vitodens 100-W)
- The control, replaced if needed (Vitodens 100-W)
- Enough heat drawn off by the system (Vitodens 200-W, 222-F, 222-W, 300-W)
- The circulation pump: fault, scale or blockage (Vitodens 200-W B2HB, 222-F B2TB, B2SB, 222-W B2LB)
- The reset with the R key (Vitodens 200-W, 222-F, 222-W, 300-W)