Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Viessmann Fault code Viessmann
E0

Fault on an external LON network device

Blocking: it retries by itself

The boiler reports a fault on an external device linked to it through the LON communication network (for example a Vitotronic 200-H control or a Vitocom). The boiler's control keeps working; that device or its link needs checking.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show E0?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code E0

The meaning depends on the boiler: find yours below.

E0

Fault of a participant on the external LON

Blocking: it retries by itself Vitodens 200-W B2HB, Vitodens 222-F B2SA, Vitodens 222-F B2SB, Vitodens 222-F B2TA, Vitodens 222-F B2TB, Vitodens 222-W B2LB, Vitodens 300-W B3HB
E0

Fault of external LON participants

Blocking: it retries by itself Vitodens 200-W B2HA, Vitodens 200-W WB2C, Vitodens 222-F FR2B, Vitodens 222-W B2LA, Vitodens 222-W WS2B, Vitodens 300-W B3HA
E0

Fault of the external LON participants

Blocking: it retries by itself Vitodens 222-F FS2B

What our technician checks

  • The LON network connections (cables and plugs)
  • The devices on the LON network (participants), for example Vitotronic 200-H or Vitocom

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.