Viessmann Fault code Viessmann
dA

Room temperature sensor of circuit 1 short-circuited

Blocking: it retries by itself

The room temperature sensor of heating circuit 1, the circuit without a mixing valve, is short-circuited: it is the sensor built into the Vitotrol 200 or 300 remote control, or a separate sensor. The boiler keeps heating, but this circuit no longer takes the room temperature into account.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show dA?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code dA

The meaning depends on the boiler: find yours below.

dA

Short circuit of the room temperature sensor of heating circuit 1 (without mixing valve)

Blocking: it retries by itself Vitodens 200-W B2HA, Vitodens 200-W B2HB, Vitodens 200-W WB2C, Vitodens 222-F B2SA, Vitodens 222-F B2SB, Vitodens 222-F B2TA, Vitodens 222-F B2TB, Vitodens 222-F FR2B, Vitodens 222-F FS2B, Vitodens 222-W B2LA, Vitodens 222-W B2LB, Vitodens 222-W WS2B, Vitodens 300-W B3HA, Vitodens 300-W B3HB
dA

Short circuit of the room sensor of heating circuit A1

Blocking: it retries by itself Vitodens 200 WB2A, Vitodens 200-W WB2B, Vitodens 222-W WS2A
dA

Short circuit of the room sensor of heating circuit 1 (without mixing valve)

Blocking: it retries by itself Vitodens 222-F FS2A
dA

Short circuit of the room temperature sensor of the heating circuit without mixing valve…

Blocking: it retries by itself Vitotronic 200 KO1B
dA

Short circuit Room sensor

Blocking: it retries by itself Vitotronic 200 KW1
dA

Short circuit room sensor, circuit KK

Blocking: it retries by itself Vitotronic 200 KW2, Vitotronic 300 KW3

What our technician checks

  • The room temperature sensor of heating circuit 1 (A1, or KK on the Vitotronic 200 KW2 and 300 KW3)
  • The sensor built into the Vitotrol 200 or 300, or the external sensor of the Vitotrol 300

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.