Viessmann Fault code Viessmann
C7

Circuit 1 pump: communication lost

Blocking: it retries by itself

The controller no longer communicates with the variable-speed pump of heating circuit 1, the circuit without a mixing valve, a pump fitted outside the boiler (circuit A1 on a Vitodens 200-W WB2B, 200 WB2A or 222-W WS2A; on a Vitodens 300-W B3HB the external pump, no circuit named); on a Vitotronic 300 KW3 it is the pump of mixing circuit M2, and on a Vitotronic 200 KW1 or KW2 the heating circuit pump is wrongly coded. The boiler keeps heating, but that pump runs at full speed (on a Vitotronic 200 KW1 or KW2 the control simply keeps regulating) and our technician needs to check the setting.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show C7?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code C7

The meaning depends on the boiler: find yours below.

C7

Communication fault with the external speed-controlled heating circuit pump, heating…

Blocking: it retries by itself Vitodens 200-W B2HA, Vitodens 200-W WB2C, Vitodens 222-F FR2B, Vitodens 222-F FS2A, Vitodens 222-F FS2B, Vitodens 222-W WS2B, Vitodens 300-W B3HA
C7

Communication error with the external speed-controlled heating circuit pump, heating circuit A1

Blocking: it retries by itself Vitodens 200-W WB2B
C7

Communication error of the external speed-controlled heating circuit pump, heating circuit A1

Blocking: it retries by itself Vitodens 222-W WS2A
C7

Communication fault of the external speed-controlled pump

Blocking: it retries by itself Vitodens 300-W B3HB
C7

Incorrect coding of the heating circuit pump

Blocking: it retries by itself Vitotronic 200 KW1
C7

Incorrect coding of the heating circulation pump

Blocking: it retries by itself Vitotronic 200 KW2
C7

Communication fault variable speed circulation pump, heating circuit M2

Blocking: it retries by itself Vitotronic 300 KW3
C7

Communication error of the externally speed-controlled heating circuit pump, heating circuit A1

Blocking: it retries by itself Vitodens 200 WB2A

What our technician checks

  • The setting of coding address E5 in the controller
  • The position of the pump's coding switches (Vitodens 222-W WS2A and 200 WB2A: 1 ON, 2 OFF; Vitotronic 200 KW1, 200 KW2, 300 KW3)

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.