Circuit 2 pump: communication lost
Blocking: it retries by itself
The controller no longer communicates with the variable-speed pump of heating circuit 2, the circuit with a mixing valve, a pump fitted outside the boiler (circuit M2 on a Vitodens 200-W WB2B, 200 WB2A or 222-W WS2A, M1 on a Vitotronic 200 KW2 or 300 KW3 control); on a Vitotronic 200 KW1 the code means the heating circuit pump is wrongly coded. The boiler keeps heating, but that pump runs at full speed (on a Vitotronic 200 KW1 the control simply keeps regulating) and our technician needs to check the setting.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show C6?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code C6
The meaning depends on the boiler: find yours below.
Communication fault with the external speed-controlled heating circuit pump, heating…
Communication error with the external speed-controlled heating circuit pump, heating circuit M2
Communication error of the external speed-controlled heating circuit pump, heating circuit M2
Incorrect coding of the heating circuit pump
Faulty communication variable speed circulation pump, heating circuit M1
Communication error of the externally speed-controlled heating circuit pump, heating circuit M2
What our technician checks
- The setting of coding address E5 in the controller
- The position of the pump's coding switches (Vitodens 222-W WS2A and 200 WB2A: 1 OFF, 2 ON; Vitotronic 200 KW1, 200 KW2, 300 KW3)