Viessmann Fault code Viessmann
bE

Vitotrol remote control fault

Blocking: it retries by itself

On most boilers the controller no longer communicates with the Vitotrol remote control of heating circuit 3, with a mixing valve (circuit M2 on a Vitotronic 300 KW3, no circuit named on a Vitotronic 200 KW1), and the boiler keeps heating without it. On a Vitodens 200-W WB2B, 200 WB2A, 222-F FS2A, 222-W WS2A or a Vitotronic 200 KW2, the same code means the remote control is wrongly coded (its coding switches), and the boiler keeps running.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show bE?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code bE

The meaning depends on the boiler: find yours below.

bE

Communication fault of the Vitotrol remote control for heating circuit 3 (with mixing valve)

Blocking: it retries by itself Vitodens 200-W B2HA, Vitodens 200-W B2HB, Vitodens 200-W WB2C, Vitodens 222-F B2SA, Vitodens 222-F B2SB, Vitodens 222-F B2TA, Vitodens 222-F B2TB, Vitodens 222-F FR2B, Vitodens 222-F FS2B, Vitodens 222-W B2LA, Vitodens 222-W B2LB, Vitodens 222-W WS2B, Vitodens 300-W B3HA, Vitodens 300-W B3HB
bE

Incorrect coding of the Vitotrol remote control

Blocking: it retries by itself Vitodens 200 WB2A, Vitodens 200-W WB2B, Vitodens 222-F FS2A, Vitodens 222-W WS2A, Vitotronic 200 KW2
bE

Communication fault of the Vitotrol remote control for the heating circuit with mixing…

Blocking: it retries by itself Vitotronic 200 KO1B
bE

Communication error Vitotrol remote control

Blocking: it retries by itself Vitotronic 200 KW1
bE

Communication fault Vitotrol remote control, heating circuit M2

Blocking: it retries by itself Vitotronic 300 KW3

What our technician checks

  • The remote control's connections and cable
  • Coding address A0 in the controller
  • The remote control's settings
  • Wireless remote control: the radio link, with the remote moved closer to the boiler or to its radio base
  • The position of the remote control's coding switches (Vitodens 200-W WB2B, 200 WB2A, 222-F FS2A, 222-W WS2A, Vitotronic 200 KW1, 200 KW2)
  • The Vitotrol remote control itself (Vitotronic 300 KW3)

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.