Circuit 2 remote control: connection lost
Blocking: it retries by itself
The controller no longer communicates with the Vitotrol remote control of heating circuit 2, with a mixing valve (circuit M1 on a Vitotronic 200 KW2 or 300 KW3, no circuit named on a Vitotronic 200 KW1). The boiler keeps heating, but the controller works without the remote control.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show bd?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code bd
The meaning depends on the boiler: find yours below.
Communication fault of the Vitotrol remote control for heating circuit 2 (with mixing valve)
Communication error of the Vitotrol remote control, heating circuit M2
Communication fault of the Vitotrol remote control for the heating circuit with mixing…
Communication error Vitotrol remote control
Faulty communication Vitotrol remote control, heating circuit M1
What our technician checks
- The remote control's connections and cable
- Coding address A0 in the controller
- The remote control's settings
- Wireless remote control: the radio link, with the remote moved closer to the boiler or to its radio base
- The remote control's coding switches (Vitodens 200-W WB2B, 200 WB2A, 222-F FS2A, Vitotronic 200 KW1)
- The Vitotrol remote control itself (Vitotronic 300 KW3)