Viessmann Fault code Viessmann
b8

Flue gas temperature sensor open circuit

Breakdown: the boiler is stopped

The sensor that measures the flue gas temperature (on a Vitopend 100-W, the flue gas monitoring sensor) has an open circuit, in the sensor itself or in its cable. On a Vitodens 200-W B2HB, 222-F B2TB or B2SB, or 222-W B2LB, the boiler locks out and only starts again after a reset; on the other Vitodens and on the Vitopend, the burner stays blocked until the sensor is repaired; on a floor-standing boiler with a Vitotronic control (KC2B, KO1B, KW1, KW2 or KW3), the boiler keeps running.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. On a Vitodens 200-W B2HB, 222-F B2TB or B2SB, or 222-W B2LB, the boiler locks out: one reset is allowed.
  3. Reset the boiler once only.
  4. If the code comes back, do not keep trying and do not take anything apart: call us.
  5. On the other models the burner is only blocked or the boiler keeps running: do not reset it.
  6. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show b8?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code b8

The meaning depends on the boiler: find yours below.

b8

Open circuit of the flue gas temperature sensor

Breakdown: the boiler is stopped Vitodens 100-W B1HA, Vitodens 100-W B1HC, Vitodens 100-W WB1B, Vitodens 100-W WB1C, Vitodens 200 WB2A, Vitodens 200-W B2HA, Vitodens 200-W B2HB, Vitodens 200-W WB2C, Vitodens 222-F B2SA, Vitodens 222-F B2SB, Vitodens 222-F B2TA, Vitodens 222-F B2TB, Vitodens 222-F FR2B, Vitodens 222-F FS2B, Vitodens 222-W B2LA, Vitodens 222-W B2LB, Vitodens 222-W WS2B, Vitodens 300-W B3HA, Vitodens 300-W B3HB, Vitotronic 100 KC2B, Vitotronic 200 KO1B
b8

Open circuit of the flue gas sensor

Blocking: it retries by itself Vitodens 200-W WB2B, Vitodens 222-F FS2A, Vitodens 222-W WS2A
b8

Open circuit of the flue gas monitoring sensor

Blocking: it retries by itself Vitopend 100-W A1JA, Vitopend 100-W WH1D
b8

Open circuit Flue gas sensor

Blocking: it retries by itself Vitotronic 200 KW1
b8

Open circuit flue gas sensor

Blocking: it retries by itself Vitotronic 200 KW2, Vitotronic 300 KW3

What our technician checks

  • The flue gas temperature sensor and its connecting cable
  • The flue gas monitoring sensor (Vitopend 100-W)
  • Without a flue gas temperature sensor: coding 1F:0 in the Boiler group (Vitotronic 100 KC2B, 200 KO1B)

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.