Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Viessmann Fault code Viessmann
b4

Internal fault in the control electronics

Blocking: it retries by itself

The controller reports an internal fault in its electronics. The boiler keeps heating, but in a fallback mode: on a Vitodens the controller heats as if it were 0 °C outside, on a Vitotronic 200 KW1 or KW2 control it switches to the chimney sweep's flue gas test mode and on a Vitotronic 300 KW3 to constant operation; the fault needs our technician.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show b4?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code b4

The meaning depends on the boiler: find yours below.

b4

Internal fault

Blocking: it retries by itself Vitodens 200 WB2A, Vitodens 200-W WB2B, Vitodens 222-F B2SA, Vitodens 222-F B2SB, Vitodens 222-F B2TA, Vitodens 222-F B2TB, Vitodens 222-F FS2A, Vitodens 222-W B2LA, Vitodens 222-W B2LB, Vitodens 222-W WS2A, Vitotronic 200 KW1, Vitotronic 200 KW2, Vitotronic 300 KW3

What our technician checks

  • The controller, to be replaced (Vitodens)
  • The electronic circuit board of the Vitotronic control (200 KW1, 200 KW2, 300 KW3)

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.