OpenTherm link lost or internal pump blocked
Blocking: it retries by itself
On a Vitodens 100-W B1HC, B1HA, WB1C, WB1B or WB1A, A9 means the boiler no longer communicates with the connected OpenTherm remote control: it keeps controlling the heating without it. On a Vitodens 200-W B2HB, 222-F, 222-W B2LB or 300-W, it means the internal circulation pump is blocked: the burner runs at reduced output if a heating circuit with a mixing valve is connected, and is blocked if only a circuit without a mixing valve is connected.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show A9?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code A9
The meaning depends on the boiler: find yours below.
Communication fault of the Open-Therm device
Communication fault of the Open Therm device
Internal circulation pump blocked
Communication error of the Open Therm device
What our technician checks
- The OpenTherm remote control's connections and cable, replaced if needed (Vitodens 100-W)
- The internal circulation pump (Vitodens 200-W B2HB, 222-F, 222-W B2LB, 300-W)