Temperature limiter short to earth
Breakdown: the boiler is stopped
On a Vitodens 200-W B2HB, 222-F B2TB or B2SB, or 222-W B2LB, the temperature limiter, its cables or its plugs touch an earthed part (short to earth): the burner stops and may lock out, and the boiler then only starts again after a reset. On a Vitodens 100-W B1HF, code 74 reports a water pressure in the system that is too low: the burner and the pump stop, with no heating and no hot water, until the pressure is restored.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Vitodens 100-W B1HF: check the system pressure on the display. Below 1.0 bar, top up with water or call us.
- Code 74 on a Vitodens 100-W B1HF: the burner is not locked out, do not reset the boiler.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show 74?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 74
The meaning depends on the boiler: find yours below.
Short circuit to earth of the temperature limiter
Short circuit to earth of the safety temperature limiter
System pressure too low
What our technician checks
- The temperature limiter, its cables and its plugs: no contact with an earthed part
- The reset with the R key, once the contact is cleared
- Topping up the water and venting the system (Vitodens 100-W B1HF)
- The system pressure sensor, compared with an external gauge (Vitodens 100-W B1HF)
- The expansion vessel pre-charge pressure (Vitodens 100-W B1HF)
- The system pressure set point and its range (Vitodens 100-W B1HF)