Gas pressure switch prevents burner start
Breakdown: the boiler is stopped
On a Vitodens 200-W B2HB, 222-F B2TB or B2SB, or 222-W B2LB, the gas pressure switch, which watches the gas pressure, stops the burner from starting: the burner stays blocked while the cause is there, without locking out. On a Vitodens 100-W B1HF, code 70 reports an internal fault of the central electronic module (HBMU): the burner locks out and the boiler stops.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check that the boiler's gas tap is open.
- Code 70 on a Vitodens 200-W B2HB, 222-F B2TB or B2SB, or 222-W B2LB: the burner is not locked out, do not reset the boiler.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show 70?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 70
The meaning depends on the boiler: find yours below.
The gas pressure switch prevents the burner from starting
Internal fault of the HBMU central electronics module
What our technician checks
- The gas supply and its pressure
- The gas pressure switch operation, with plug 111 pulled to see whether the burner starts
- The HBMU central electronic module, to be replaced (Vitodens 100-W B1HF)